Data:
P3-HC6D versions: 9 different intensification factors
PIN: 20 – 207 bar
PH: 800 bar maximum
PRETURN: As low as possible (return pressure to tank)
POUTLET: PH = (PIN – PRETURN) x intensification factor
Mounting: Inline tube
Weight: 120.0 kg.
Description
The P3-HC6D is a high-flow dual-acting unit, consisting of three parallel mounted HC6D boosters, which is capable of delivering up to 195.0 l/min flow on the high-pressure end.
Like other miniBOOSTER models, the P3-HC6D raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. Relative to its flow capability, the P3-HC6D is a compact unit weighting 120 kg.
Flow rates
Intensification factor i | Max. intensified outlet flow l/min | Max. inlet flow l/min |
---|---|---|
1.2 | 195.0 | 240.0 |
1.5 | 159.0 | 240.0 |
2.0 | 120.0 | 240.0 |
2.5 | 102.0 | 240.0 |
3.3 | 76.8 | 240.0 |
4.0 | 63.6 | 240.0 |
4.9 | 51.6 | 240.0 |
6.3 | 40.2 | 240.0 |
8.2 | 31.2 | 240.0 |
Functions
The basic operation is illustrated in the function diagram. Oil is fed through the directional valve CV to the IN port, flowing freely through the check valves 2x KV1, 2x KV2 and DV to the high-pressure side H. In this condition maximum flow through the booster is achieved giving a fast-forward function.
When pump pressure is reached on the high-pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the oscillating pump units OP1 and OP2 by turns. The unit will automatically stall when end pressure on high-pressure side H is reached. If a pressure drop on the high-pressure side exists due to consumption or leakage, the OP1 and OP2 units will automatically operate to maintain the end pressure. It is possible to change the high-pressure connection H to the opposite end of the booster.
Function diagram
6D-105-00
Dimensions
Dimension drawing 6D-133-02
Connection types
Connection | IN / R | H |
---|---|---|
1 | 1 1/4" BSPP | 1 1/4" BSPP |
Fluids and materials
Additional information is available on the website under Products → General specifications.
Ordering an P3-HC6D
Ordering example of an P3-HC6D with i = 4.0, DV incorporated and BSPP connections: P3-HC6D – 4.0 – B – 1
Attention note!
The G-model is available in 2 variants, when ordering please specify accordingly:
- Dynamic – low hysteresis: Ordering example of an P3-HC6D with i = 4.0 RV incorporated and BSPP connections: P3-HC6D – 4.0 – G – 1
- Fail safe – high hysteresis: The RV valve opening ratio is to be determined on individual basis. Contact our technical support. Ordering example of an P3-HC6D with i = 4.0 RV with opening ratio x.x incorporated and BSPP connections: P3-HC6D – 4.0 – G – x.x – 1
Model
- P3-HC6D
Intensification, i
- Select factor
- See flow rate table
Model version
- Select type
- A = without DV
- B = with DV
- G = with proportional valve
Connections
- Select thread
- 1 = BSPP
Max. tightening torque BSPP
IN / R | H | |
---|---|---|
1 1/4" BSPP | 1 1/4" BSPP | |
with steel washer | 35.0 da/Nm | 35.0 da/Nm |
with cutting edge | 35.0 da/Nm | 35.0 da/Nm |