M-HC28

Data:

 

M-HC28 versions: 15 different intensification factors

PIN: 20–207 bar

PH: 800 bar maximum

PRETURN: As low as possible (return pressure to tank)

POUTLET: PH = (PIN – PRETURN) x intensification factor

Mounting: Inline tube

Weight: 3.6 kg.

 

Model versions:

A model = no dump valve
B model = with dump valve
G model = direct proportionally controlled

Material certificate 3.1 on request

Description

The M-HC28 incorporates an adjustable pressure relief valve on the high pressure side. The pressure relief valve controls the maximum allowable pressure the system can output, allowing the booster to go for a higher end pressure producing flow at the decided pressure.

The M-HC28 raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure.

An optional orifice can be mounted in both IN- and R-ports of the booster to prevent overspeeding.

Flow rates

Intensification factor
i
Max. intensified outlet flow
l/min
Max. inlet flow
l/min
1.23.540.0
1.54.240.0
2.03.240.0
2.22.940.0
2.52.740.0
2.82.540.0
3.22.540.0
4.02.040.0
5.01.640.0
6.61.340.0
9.00.940.0
13.00.640.0
16.00.540.0
20.00.340.0
25.00.240.0

Functions

The basic operation is illustrated in the function diagram. Oil is fed through the directional valve CV to the IN port, flowing freely through the check valves KV1, KV2 and DV to the high-pressure side H. In this condition maximum flow through the booster is achieved giving a fast-forward function.

When pump pressure is reached on the high-pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the oscillating pump unit OP. The unit will automatically stall when end pressure on the high-pressure side H is reached. If a pressure drop on the high-pressure side exists due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.

A relief valve is installed to control the maximum allowable pressure the system can output, allowing the booster to go for a higher end pressure producing flow at the decided pressure.

Function diagram

110-00

Dimensions

Dimension drawing M-HC28-01

Connection types

ConnectionIN / R / ZH
11/4" BSPP1/4" BSPP

Adapter Drawing

Adapter ordering codes and specifications are shown in the PDF-file: 2-901-01

Fluids and materials

Additional information is available on the website under Products → General specifications.

Ordering an M-HC28

Ordering example of an M-HC28 with i = 4.0 DV incorporated and BSPP connections: M-HC28 – 4.0 – B – 1

Attention note!
Valve pre-setting is required, please specify when ordering the intensifier.

If connection adapters are required, please specify ordering code . See adapter table.
Adapters will be factory mounted.

The G-model is available in 2 variants, when ordering please specify accordingly:

  • Dynamic – low hysteresis: Ordering example of an M-HC28 with i = 4.0 RV incorporated and BSPP connections: M-HC28 – 4.0 – G – 1
  • Fail safe – high hysteresis: The RV valve opening ratio is to be determined on individual basis. Contact our technical support. Ordering example of an M-HC28 with i = 4.0 RV with opening ratio x.x incorporated and BSPP connections: M-HC28 – 4.0 – G – x.x – 1
R

Model

  • M-HC28
R

Intensification, i

  • Select factor
  • See flow rate table
R

Model version

  • Select type
  • A = without DV
  • B = with DV
  • G = with proportional valve
R

Connections

  • Select thread
  • 1 = BSPP

Max. tightening torque BSPP

IN / RH
1/4" BSPP1/4" BSPP
with steel washer4.0 da/Nm4.0 da/Nm
with cutting edge4.0 da/Nm4.0 da/Nm