HC6D

Data:

 

HC6D versions: 9 different intensification factors

PIN: 20 – 207 bar

PH: 800 bar maximum

PRETURN: As low as possible (return pressure to tank)

POUTLET: PH = (PIN – PRETURN) x intensification factor

Mounting: Inline tube

Weight: 20.0 kg.

Model versions:

A model = no dump valve
B model = with dump valve
G model = direct proportionally controlled

Material certificate 3.1 on request

Description

The HC6D is a high-flow dual-acting unit which is capable of delivering up to 65.0 l/min flow on the high-pressure end.

Like other miniBOOSTER models, the HC6D raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. Relative to its flow capability, the HC6D is a compact unit weighting 20 kg.

Flow rates

Intensification factor
i
Max. intensified outlet flow
l/min
Max. inlet flow
l/min
1.265.080.0
1.553.080.0
2.040.080.0
2.534.080.0
3.325.680.0
4.021.280.0
4.917.280.0
6.313.480.0
8.210.480.0

Functions

The basic operation is illustrated in the function diagram. Oil is fed through the directional valve CV to the IN port, flowing freely through the check valves 2x KV1, 2x KV2 and DV to the high-pressure side H. In this condition maximum flow through the booster is achieved giving a fast-forward function.

When pump pressure is reached on the high-pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the oscillating pump units OP1 and OP2 by turns. The unit will automatically stall when end pressure on high-pressure side H is reached. If a pressure drop on the high-pressure side exists due to consumption or leakage, the OP1 and OP2 units will automatically operate to maintain the end pressure. It is possible to change the high-pressure connection H to the opposite end of the booster.

Function diagram

2D-105-02

Dimensions

Dimension drawing 6D-120-05

Connection types

ConnectionIN / RH
11/2" BSPP1/2" BSPP

Fluids and materials

Additional information is available on the website under Products → General specifications.

Ordering an HC6D

Ordering example of an HC6D with i = 4.0, DV incorporated and BSPP connections: HC6D – 4.0 – B – 1

Attention note!
The G-model is available in 2 variants, when ordering please specify accordingly:

  • Dynamic – low hysteresis: Ordering example of an HC6D with i = 4.0 RV incorporated and BSPP connections: HC6D – 4.0 – G – 1
  • Fail safe – high hysteresis: The RV valve opening ratio is to be determined on individual basis. Contact our technical support. Ordering example of an HC6D with i = 4.0 RV with opening ratio x.x incorporated and BSPP connections: HC6D – 4.0 – G – x.x – 1
R

Model

  • HC6D
R

Intensification, i

  • Select factor
  • See flow rate table
R

Model version

  • Select type
  • A = without DV
  • B = with DV
  • G = with proportional valve
R

Connections

  • Select thread
  • 1 = BSPP

Max. tightening torque BSPP

IN / RH
1/2" BSPP1/2" BSPP
with steel washer13.0 da/Nm13.0 da/Nm
with cutting edge13.0 da/Nm13.0 da/Nm